Compartir
Loss of Start-Up Oxygen in CSE SR-100 Self-Contained Self-Rescuers (en Inglés)
Centers for Disease Cont And Prevention
(Autor)
·
National Institute Fo Safety and Health
(Autor)
·
D. Human Services
(Autor)
·
Createspace Independent Publishing Platform
· Tapa Blanda
Loss of Start-Up Oxygen in CSE SR-100 Self-Contained Self-Rescuers (en Inglés) - And Prevention, Centers for Disease Cont ; Safety and Health, National Institute Fo ; Human Services, D.
$ 26.62
$ 40.96
Ahorras: $ 14.33
Elige la lista en la que quieres agregar tu producto o crea una nueva lista
✓ Producto agregado correctamente a la lista de deseos.
Ir a Mis Listas
Origen: Estados Unidos
(Costos de importación incluídos en el precio)
Se enviará desde nuestra bodega entre el
Lunes 15 de Julio y el
Miércoles 24 de Julio.
Lo recibirás en cualquier lugar de Ecuador entre 1 y 3 días hábiles luego del envío.
Reseña del libro "Loss of Start-Up Oxygen in CSE SR-100 Self-Contained Self-Rescuers (en Inglés)"
This report describes a National Institute for Occupational Safety and Health (NIOSH) and Mine Safety and Health Administration (MSHA) investigation assessing the prevalence of a lack of sufficient start-up oxygen in CSE SR-100 self-contained self-rescuer (SCSR) devices. The availability of sufficient start-up oxygen is critical to the performance of the SR-100. As part of a routine field testing program of SCSRs used in coal mines, NIOSH and MSHA detected two SR-100s that lacked sufficient start-up oxygen. CSE Corporation subsequently discovered one SCSR that lacked sufficient start-up oxygen in that company's internal quality control program and voluntarily stopped further production and sales of SR-100s. NIOSH developed a protocol to test for the presence of start-up oxygen in field-deployed SR100s. The purpose of the test was to determine if the failure rate of the start-up oxygen in the population of 70,000 field-deployed units exceeded 1%. NIOSH and MSHA used American Society for Quality (ASQ), Sampling Procedures and Tables for Inspection of Isolated Lots by Attributes (ASQC Q3-1988). In assessing the SR-100s, if no more than 3 failures of start-up oxygen occurred in the 500-unit random sample, the SR-100 could be accepted as meeting the Limiting Quality (LQ) rate of 1.25% for start-up oxygen performance.
- 0% (0)
- 0% (0)
- 0% (0)
- 0% (0)
- 0% (0)
Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.
✓ Producto agregado correctamente al carro, Ir a Pagar.